News

/

Product Series: EL-SPD

SPD class II (T2), pluggable in 3+1-circuit


Fully pluggable surge protective arrester for the use in three-phase TT and TNS systems.

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

SPD class II (T2), pluggable in 3+0-circuit


Fully pluggable surge protective arrester for the use in three-phase TNC systems.

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

SPD class II (T2), pluggable in 4+0 circuit


Fully pluggable surge protective arrester for the use in three-phase TNS systems, 4+0-circuit.

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

To top

SPD class II (T2) in 2+0-circuit


Complete modul for single phase TN systems

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

To top

SPD class II (T2) in 2+1-circuit


Pluggable SPD type 2 / class II for 2-pole TT systems with code.

  • Test standard: IEC 61643-1 / EN 61643-11
  • Vibration test standard: DIN EN / IEC 60068-2-6
  • Shock test standard: DIN EN / IEC 60068-2-27
  • 2+1 circuit
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact

To top

SPD class II (T2) in 1+1-circiut


Complete modul for single phase TT and TN systems

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

To top

SPD class II (T2) in 1+0-circuit


Complete modul for application between L and N line

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

To top

SPD class II (T2) in 0+1-circuit


Complete modul summation current spark gap for application between N and PE line

  • Test standard: IEC 61643-1 / EN 61643-11
  • Mounting on 35 mm DIN rail
  • Optional remote changeover contact
  • Applicable at the boundaries LPZ 0B - 1 and higher

Datasheet NPE lightning current arrester


388198_EL-T2_0_1-NPE_v02_en_DB.pdf

EL-T2/0+1-NPE

To top

Drucken | Print |Bookmark