Download

/

Downloads

/

Datasheets

Pluggable SPD for MCR applications


Pluggable SPD with high discharge cappability for MCR applications

Fully pluggable two-parts lightning current discharge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire..

  • Test standard: IEC 61643-21 / EN 61643-21
  • Applicable at the boundaries LPZ 0B - 1 and higher
  • Mounting on 35 mm DIN rail
  • Space required for installation: 17.5 mm  

MP 2x2 GDT ST / MP 1x2 GDT ST


970007_MP_2x2_GDT_ST_v05_en_DB.pdf

Protective circuit for 4 signal lines without reference to ground potential

970010_MP_1x2_GDT_ST_v05_en_DB.pdf

Protective circuit for 2 signal lines without reference to ground potential

Pluggable SPD with high discharge cappability  and low protection level for MCR applications

Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and the-refore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire.

  • MP 2x2: Protective circuit for 4 signal lines without reference to ground potential
  • MP 1x2: Protective circuit for 2 signal lines without reference to ground potential
  • Test standard: IEC 61643-21 / EN 61643-21
  • Applicable at the boundaries LPZ 0B - 2 and higher
  • Mounting on 35 mm DIN rail
  • Enclosure material: thermoplastic
  • Space required for installation: 17.5 mm 

Pluggable SPD for high frequency MCR applications

Fully pluggable two-parts combined surge arrester for signal lines for high frequency applications such as bus systems or video transmission. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire.

  • MP 2x2: Protective circuit for 4 signal lines without reference to ground potential
  • MP 1x2: Protective circuit for 2 signal lines without reference to ground potential
  • Test standard: IEC 61643-21 / EN 61643-21
  • Applicable at the boundaries LPZ 0B - 2 and higher
  • Mounting on 35 mm DIN rail
  • Space required for installation: 17.5 mm
Drucken | Print |Bookmark